Mounting the System Control Center
IMPORTANT:
PLEASE READ THE FOLLOWING MOUNTING CON
-
SIDERATIONS BEFORE INSTALLING THE SYSTEM
CONTROL CENTER
The System Control Center is contained in a rainproof
enclosure. It is suitable for indoor or outdoor mounting. It
should mount on a flat vertical wall and MUST be positioned
so that the conduit knockouts are located at the bottom of
the enclosure. Also it is important that it is not mounted
in a confined space. The four sides need to remain free of
obstructions so that the system can dissipate heat from the
inside of the enclosure.
ATTENTION: POSITIONING THE ENCLOSURE WITH
THE KNOCKOUTS LOCATED AT THE SIDE OR TOP OF
THE ENCLOSURE MAY ALLOW WATER TO ENTER THE
SYSTEM AND CAUSE DAMAGE TO THE SYSTEM AND/OR
CREATE AN ELECTRICAL SHOCK HAZARD.
The System Control Center should be located as close as
possible to the pumps, heater, valves and sensors that are
required to be connected to it. Be sure that the system
and all other electrical components are at least 5’ (3m for
Canada) from the edge of the pool or spa. When selecting
the mounting position, plan how the 1” rigid conduit carrying
the power to the System Control Center will be routed. Also
plan for the routing of the flexible conduit that will run to
the pumps, lights and heater. Remember to consider the
length of the sensor wires & valve wires when selecting
the final location. The cell cord for the chlorine generator
is 10’ long, the cable length on the Air Temperature Sensor
is 10’ long and the Water Temperature Sensor is 25’ long.
They must reach connector receptacles located inside the
system. Additionally, the location selected should have clear
access in front of the system to permit the owner or service
personnel to stand in front of the System Control center
unobstructed by other equipment.
ATTENTION: BE SURE THE LOCATION CHOSEN FOR THE
SYSTEM CONTROL CENTER ALLOWS UNOBSTRUCTED
ACCESS TO THE GFCI PROTECTING THE UNDERWATER
LIGHT CIRCUIT. THE GFCI IS LOCATED ON THE RIGHT
SIDE OF THE BOX.
MOUNTING THE SYSTEM CONTROL CENTER
The Main System Control Center is a Permanently
Connected Control.
After selecting a location with the mounting
considerations (on this page), and any requirements
of national, state or local codes in mind, mount
the enclosure.
If the mounting substrate will allow, mount the System
Control Center by driving mounting screws through the
holes provided in the brackets at the top and the bottom
of the enclosure and into the wall.
If wall anchors must be used, hold the System Control Center
enclosure in position and mark the hole pattern on the wall.
Drill and set the anchors; fasten the enclosure with screws.
Be sure to position the Main Control Center level and square
for a neat installation.
After mounting the System Control Center, open the
enclosure door and remove the six screws securing the
interior cover to access the connections to the electrical
components. The enclosure door can be removed
for ease of wiring. To remove the door, open it wide
enough to clear the edge of the enclosure and then lift
straight up.